RTK GMC Microgas flowmeter

RTK GMC micro gas flowmeter, using the bubble method measurement principle, can accurately measure the volume of ultrafine gas (as low as 0.03mL/H). It is widely used in chemical hydrogen storage/hydrogen production (amborane, hydrazine hydrate, sodium borohydride, formic acid, magnesium hydride, etc.), photolytic water hydrogen production, biological hydrogen production (photolytic hydrogen production and photolytic fermentation and dark fermentation coupled hydrogen production), animal feed and nutrition research (rumen in vitro fermentation).

Brand: RTKINS

Model: RTK GMC

  • Introduction
  • Technical
  • System
  • Service
  • Message
Contact
Introduction

The RTK Ultra-Micro gas flowmeter is a high precision gas flowmeter developed by RTK for the laboratory with an accuracy of up to 30 microliters (μL). The ability to measure gas volumes very accurately makes it particularly suitable for scientific experiments with very little gas production (milliliters to escalators). There are multiple options for single and multi-channel.


Technical advantages

Technological advantage

(1) Multi-channel parallel experiments can be done to improve work efficiency;

(2) Product miniaturization: length, width and height 45*25*22cm, does not occupy laboratory space;

(3) High measurement accuracy: different measurement accuracy can be selected according to demand, up to 30 microliters (μL);

(4) Measuring range: 30μL/ H-2L /h

(5) Measurement accuracy: < 1%

(6) Can integrate pH module, real-time online test pH value, suitable for some reaction systems that need to monitor pH value, such as various microbial fermentation, chemical catalytic systems, etc.;

(7) Suitable for the measurement of all kinds of gases, using special materials, can be used for the measurement of corrosive gases;

(8) After gas measurement, it can be directly discharged, or collected by a gas collection device for further analysis;

(9) Software real-time, automatic, online measurement and record data.


System parameter

The difference between single channel and multi-channel

1.Single channel has two modes: screen display data and software record data. Multichannel data can only be recorded through software.


2. The single channel has a temperature and pressure sensor, which can be converted into the standard condition volume in real time, which is suitable for occasions with large temperature and pressure changes, especially for long-term testing, such as span seasonal testing. The multi-channel temperature and pressure sensor is suitable for situations where the temperature and pressure are relatively stable, such as testing in an air-conditioned room


3. Single channel is suitable for applications where the gas production rate varies greatly, such as chemical catalytic hydrogen production. Up to 9 single-channel data can be integrated in the same software interface. Multi-channel is suitable for applications where the gas production rate is relatively small and uniform.


Hubei Loktec Instrument Co., LTD., founded in 2013, is a state-level high-tech enterprise with nearly 30 patent certificates (including invention patents) in the field of biodegradation. It is the Joint Laboratory of Anaerobic Fermentation of China Agricultural University and the cooperative base of industry-university-research of Huazhong Agricultural University. It is also a pioneer and leader in the field of biodegradation detection instruments in China.


Welcome to inquire!


Online Message
Fill in the following information, and we will contact you in the shortest time (strictly protect the information from disclosure, please fill in with confidence)

* Name:

* Company:

* Phone:

Explain:

* Verification Code:

invisibility? Click Replace
洛克泰克仪器
Contact
Tel:027-87024316
18901354771

Wechat

18901354771

Wechat